LinMot限制最大電流

最大電流可在easy step中設定如下: Parameters> Easy Steps >IO Motions LinMot有6組IO可使用 可任選其一作為電流限制功能 Ex. 1.  設定X14.15 config > X14.15 Rising Edge Fuction→Goto Abs position with Max Current 2. X14.15 config > X14.15 IO Motion Config→Maximal Current可變更電流數值 3.  設定完成後啟動X14.15即可限制電流最大值 Control Panel > IO Panel→勾選選定的IO接腳(手可擋住的推力約為1~2A)

LinMot Command Table如何用IO觸發

LinMot 原廠軟體 LinMot Talk 可撰寫一連串的動作指令 指令設定完成後可直接用IO觸發執行 1. 點選 Parameters/ Command Table需要的動作參數可一步步設定在Table中 2. 第一行設定用input3觸發動作 Input3設定如下:Parameters/ Easy Steps / IO Motions / InputX14.15 Config/ X14.15 Rising Edge Function>>設為Eval Command Table Command 如圖: 3. 接著請設定 X14.15 IO Motion Config 如圖:Curve/ Cmd ID >設定為 1 也就是直接觸發Command Table 第一行 4. 設定IO可觸發動作停止 在Command Table中先寫好停止指令 如圖:ID 31設定為停止動作 5.  設定 input4 為停止動作 Input4 設定如下:Parameters/ Easy Steps / IO Motions / InputX14.3 Config/ X14.3 Rising Edge Function>>設為Eval Command Table Command 6. 接著請設定 X14.3 IO Motion Config如圖: Curve/ Cmd ID >設定為31 也就是直接觸發Command Table 31行

LinMot P01-37S Homing設定

LinMot P01-37S系列因為peak current達15A,  所以電源供應器的電流量也需要注意, 若電源供應器未達15A, 有可能LinMot驅動器會因電壓不足而產生安全機制出現Error 若要避免可在LinMot talk設定電流額度 參數位置:Parameters> Motion Contrl SW > State Machine Setup > Homing > Homing Posion ConfigCurrent Limit Default 值為100%可依據情況縮小額度例如改為70%等如圖:

LinMot開機時停止firmware的方法

If you want to login over RS232 you have to stop the firmware of the controller. How this is done is explained below. 1) Choose “Install Firmware” 2) Now take the script “StopFirmware”: 3) Before choosing the device port please switch off the 24VDC power supply of the controller. 4) Then press Ok and switch on the 24VDC power supply. Attention: you have around 2 seconds after pressing Ok to switch on the 24VDC power supply! 5) The following message shows, that you are now able to login. 6) You can now login as usual and change settings. As soon as you press reboot in LinMot-Talk the connection will be lost again.

LRS如何作動?

https://montrol.com.tw/wp-content/uploads/2012/02/04.-LRW線性滑軌:600mm高速測試2.mp4https://montrol.com.tw/wp-content/uploads/2012/02/03.-LRW線性滑軌:600mm高速測試.mp4

LinMot使用於line-scan(線掃瞄)測試

運用LinMot內建磁性尺做為取像trigger =================測試設備=================LinMot G01LinMot B1100Dalsa PX4 seriesNikon 50mmAVA 2 – EM2 4010 =================硬體接線================= LinMot            ———     Dalsa A+ (13.9)         ———      A+   (紅) A- (13.2)          ———      A-    (橙) B+(13.10)        ———      B+   (紫) B-(13.3 )          ———      B-   (藍) OUT1(14.17)   ———      Trigger+  (白) GND(14.1)       ———      Trigger-  (黑) =================測試小記=================1.應要有Trigger2.應以position為參考3.檯面剛性會造成量測有誤差